U.S. Manufacturing · U.S. Sales & Engineering Support
+1-626-698-2209info@artecocold.comRequest a Quote
PIR Insulated Sandwich Panels

Why Arteco

  • U.S. manufacturing and assembly
  • Engineering selection support
  • Pressure-tested before shipment
  • Spare parts and documentation

PIR Insulated Sandwich Panels

Category: Sandwich Panels

PIR Insulated Sandwich Panels are the versatile workhorse of insulated construction: one panel platform serving exterior walls, internal partitions, ceilings and retrofit linings across chill, frozen and controlled-temperature applications. The polyisocyanurate core insulates at 0.022 W/mK, the non-flammable rating satisfies fire-conscious specifications, and thickness options from 40mm to 200mm mean a single material family can envelope an entire facility – storage rooms, processing zones, corridors and plant spaces – with consistent appearance and detailing throughout.

Key Features and Benefits

  • One platform, many roles: exterior envelope, internal temperature-zone partitions, suspended ceilings and refurbishment linings all use the same joint system and finish family.
  • Thermal conductivity of 0.022 W/mK provides genuine cold-room-grade insulation in thinner build-ups than fibrous alternatives.
  • Non-flammable PIR core keeps fire documentation straightforward for both exterior walls and internal partitions.
  • Core density of 40 kg/m³ gives panels the rigidity needed for ceiling spans and partition heights without secondary framing.
  • Steel, galvanized and stainless facings adapt appearance and hygiene class room by room while keeping detailing consistent.
  • Effective width 1000mm and lengths from 2m to 12m suit both large warehouse walls and compact service rooms.
  • Approximately 30 dB acoustic insulation makes the panels effective as noise barriers around compressor rooms.
  • Future facility changes are simple: partitions can be relocated or extended with matching panels from the same system.

Typical Applications

Facilities that use the panel across all roles include food logistics parks where insulated walls, inter-room partitions and ceilings share one specification; multi-tenant cold warehouses fit out zone by zone; processing plants dividing chill, frozen and ambient areas within a single hall; supermarkets with back-of-house storage rooms built inside retail buildings; and laboratories or pharmaceutical suites requiring stable, cleanable controlled-temperature spaces. The system’s versatility also supports phased development – owners can construct shell buildings and fit out temperature zones later as tenants and products are confirmed, without redesigning the envelope each time.

Planning a Multi-Role Envelope with One Panel System

When one facility needs exterior insulation, internal zoning and acoustic separation, specifying different materials for each role creates interface problems: mismatched thicknesses at junctions, incompatible joints, and different maintenance needs. A unified panel approach avoids all of it. Exterior walls carry the weather and insulation duty at freezer-grade thickness; internal partitions reuse the same profile at reduced thickness where temperature differences are smaller; ceilings use the same facings so appearance stays consistent room to room. Junction details repeat, installation crews learn one system, and spare panels kept on site serve any future modification. The engineering task becomes selecting the right thickness and facing per room rather than managing several material systems – which is exactly how we scope each project, room by room, before production begins.

Manufacturing Quality and Project Support

Continuous double-belt lamination keeps core properties consistent across every thickness and facing combination. Panels are cut to project lists, inspected for dimensional accuracy and packed by zone so installation proceeds logically. Arteco prepares the room-by-room specification, layout drawings and junction details, and coordinates panels with doors, penetrations and refrigeration equipment so the complete envelope performs as one system.

Frequently Asked Questions

Can the same panels be used for walls and ceilings?

Yes. Ceiling installations use the same panels with appropriate support spacing detailed per thickness and span. Consistent facings keep the visual finish uniform between walls and ceilings.

How do partitions connect to exterior walls without cold bridges?

Partition-to-envelope junctions use matching joint profiles and sealant details that maintain thermal continuity. We draw every junction type in the layout package so nothing is improvised on site.

Is 40mm thickness useful for anything in a cold facility?

Thin panels serve ambient partitions, corridor linings, plant room enclosures and acoustic screens within the same building – keeping appearance consistent while saving cost where heavy insulation is unnecessary.

Can partitions be relocated later if the layout changes?

Yes. Panels join mechanically rather than by adhesive, so partitions can be disassembled, reconfigured and re-erected with replacement sealants. Many facilities plan for this flexibility from day one.

How are different hygiene levels handled in one building?

Facing selection varies by room – stainless for washdown areas, coated steel elsewhere – while the panel platform, joints and detailing stay identical, giving consistent construction quality across all hygiene classes.

Planning Multi-Role Projects Room by Room

Facilities using one panel family across walls, partitions and ceilings benefit from a structured specification process. Start with the room schedule: list each space with its temperature duty, hygiene class and acoustic requirement. Thickness follows temperature – envelope walls carry the full differential, internal partitions less. Facing follows hygiene – stainless for washdown rooms, coated steel elsewhere. Acoustic duty marks rooms where the panel’s damping value contributes. From this schedule, the layout develops wall by wall, with junctions between different constructions detailed where they meet. The output is a coherent envelope specification where every room has exactly the construction its duty requires, and nothing is over- or under-specified. We prepare this room-by-room schedule with every multi-role project, so owners can see – and approve – exactly what each space receives before production begins.

Can you convert our architectural drawings into a panel specification?

Yes. Provide the plans with room temperatures and hygiene requirements; we produce the room-by-room panel schedule and layout drawings for your approval.

Technical Specifications

SpecificationValue
Panel Thickness40mm, 50mm, 75mm, 100mm, 150mm, 200mm
Standard FacingsSteel sheet / Galvanized sheet / Stainless steel
Core Material Density40 kg/m³
Thermal Conductivity0.022 W/mK
Acoustic Insulation30 dB
Standard Length2m-12m
Effective Width1000mm
Fire ResistanceNon-flammable

Send Inquiry