U.S. Manufacturing · U.S. Sales & Engineering Support
+1-626-698-2209info@artecocold.comRequest a Quote
Hot Sales Cold Room Panel

Why Arteco

  • U.S. manufacturing and assembly
  • Engineering selection support
  • Pressure-tested before shipment
  • Spare parts and documentation

Hot Sales Cold Room Panel

Category: Sandwich Panels

The Hot Sales Cold Room Panel is our most-ordered insulated panel configuration – the specification that repeat customers return to because it performs predictably across the widest range of cold storage duty. Polyurethane core at 0.022 W/mK conductivity and 40 kg/m³ density, thicknesses from 40mm to 200mm, steel or galvanized facings and the proven tongue-and-groove joint system: a combination refined by years of production and field feedback into a dependable default for chill rooms, freezer rooms and insulated partitions.

Key Features and Benefits

  • Field-proven configuration: the thickness, core and facing combinations behind this panel are our highest-volume production standard.
  • Thermal conductivity of 0.022 W/mK insulates rooms from chill to deep-freeze duty within one panel family.
  • Six thicknesses from 40mm to 200mm let each room be engineered to its temperature without special-order delays.
  • Standardized production means short lead times and stable pricing for program and multi-site projects.
  • Steel and galvanized facings cover the majority of storage environments; stainless available for hygiene-critical rooms.
  • Core density held at 40 kg/m³ keeps panels rigid, joints tight and insulation performance consistent batch to batch.
  • Approximately 30 dB acoustic insulation adds comfort value in occupied buildings.
  • Extensive installation history means our detailing, junction and door coordination guidance reflects thousands of completed rooms.

Typical Applications

The configuration serves the mainstream of cold chain construction: walk-in coolers and freezers for food retail and hospitality, distribution cold rooms, produce storage facilities, meat and dairy stores, pharmaceutical chill suites and insulated partitions in processing plants. It is the specification chain operators standardize across branches because it is always available and always the same, and the default our engineers recommend when a project’s duty falls within its proven envelope – which covers the large majority of temperature-controlled rooms we supply.

Why Standardization Wins Cold Chain Programs

Every cold storage operator eventually faces the same question: custom-engineer each room, or standardize? Custom optimization squeezes marginal gains from individual rooms but multiplies complexity – different specifications, different lead times, different spares, and knowledge that does not transfer between sites. Standardization inverts the economics: one proven panel definition shortens procurement, stabilizes cost, simplifies installation training and makes maintenance predictable across the entire estate. The configuration behind this panel earned its position exactly this way – through repeat orders from operators who value rooms that behave identically at every location. Standardization also de-risks expansion: when a new site is confirmed, panels are already specified, tooling is set, and the supply schedule is known. Where a specific room falls outside the standard range – extreme temperatures, unusual hygiene classes – we engineer the exception without disturbing the standard everywhere else.

Manufacturing Quality and Project Support

High-volume production runs keep core properties consistent and pricing stable; panels are inspected for density, adhesion and dimensional accuracy before packing by position. Arteco provides heat-load validation, layout drawings and junction details for each project, and coordinates panels with doors and refrigeration equipment. Because the configuration is continuously in production, replacement and extension panels ship on short notice throughout the facility’s life.

Frequently Asked Questions

Why is this configuration the most popular?

It covers the widest duty range with the shortest lead times: standard thicknesses are continuously produced, and the joint and facing options serve most room types. Repeat customers standardize on it for predictability.

Can I still customize thickness or facing within this line?

Yes. All six thicknesses and three facing families remain available; the “standard” designation reflects production priority and availability, not restriction.

How quickly can panels ship?

Standard configurations move fastest because production runs continuously. We confirm the schedule at order; urgent projects can often be accommodated within regular production slots.

Is this panel suitable for freezer rooms?

Yes – 150mm and 200mm thicknesses in this configuration serve freezer and deep-freeze duty. Thickness is selected per room temperature through our standard heat-load calculation.

What support comes with the panels?

Layout drawings, junction and door details, installation guidance and technical follow-up. Refrigeration equipment and doors can be quoted as part of the same package.

Standardization Across Multi-Site Programs

Operators running cold storage across multiple sites gain compounding benefits from standardizing one panel configuration. Procurement simplifies: one specification, one approval cycle, one price basis across the entire estate. Installation knowledge transfers between sites – crews work the same joints, the same details, the same hardware, so every project after the first runs faster. Maintenance becomes predictable: spare panels, sealants and components are identical everywhere, and trades know exactly what they will find behind any wall. Expansion decisions accelerate because the supply schedule for the standard configuration is known in advance. The configuration behind this panel supports exactly this operating model, which is why chain operators and franchise programs adopt it estate-wide. Where an individual site needs an exception, we engineer it without disturbing the standard elsewhere.

Can you support a standardized specification across our sites?

Yes. We maintain the standard configuration, provide site-specific layouts and schedules for each project, and keep documentation consistent so your teams work from one specification everywhere.

Technical Specifications

SpecificationValue
Panel Thickness40mm, 50mm, 75mm, 100mm, 150mm, 200mm
Standard FacingsSteel sheet / Galvanized sheet / Stainless steel
Core Material Density40 kg/m³
Thermal Conductivity0.022 W/mK
Acoustic Insulation30 dB
Standard Length2m-12m
Effective Width1000mm
Fire ResistanceNon-flammable

Send Inquiry